Solé Diesel generators are compact, reliable, low-impact sound and long-lasting.

 

1500 and 1800 RPM ranges offer 6 kVA up to 180 kVA of power.
Some models run at 3000rpm.
Our latest range is high speed variable, 2200-3000rpm. See below.

 

All our models offer single-phase or three-phase input and also an option to incorporate sound shield canopy.

 

Wide variety of models with Type Approval certification and other options such as parallel operation.

NEW Variable speed gen set range:

Introducing the new range of Variable Speed gen sets. 

 

With our new range, the engine speed of the gen set adjusts to match the electrical demand at the time. This dynamic management system, governed by electronic control is “live” and ensures only the energy required is produced and consumed.

 

Benefits

 

Extended Service Life & Optimised Maintenance – strain and wear and tear on all systems is reduced by the variable speed, giving a more stable performance and a longer life.

 

Compact design – a new style of alternator is required to handle the variable speed design and it is much more compact than traditional alternators. Perfect for vessels with higher power out requirements but limited space.   
VSC models are the most compact in our range.

50Hz range:

4 GSCH V3

Power kVA:  3 kVA

Frequency:  50Hz

RPM:                 3,000

Phase:            Single

Data sheet pdf

7 GS/GSC

Power kVA:  6.6 kVA

Frequency:  50Hz

RPM:                 1,500

Phase:            Single

Data sheet pdf

8 GT/GTC​

Power kVA:  7.8 kVA

Frequency:  50Hz

RPM:                 3,000

Phase:            Three

Data sheet pdf

G-8M-3

Power kVA:  8 kVA      Space Saver

Frequency:  50Hz     No canopy option

RPM:                 3,000

Phase:            Single

Data sheet pdf

G-8T-3

Power kVA:  8 kVA     Space Saver

Frequency:  50Hz     No canopy option

RPM:                 3,000

Phase:            Three

Data sheet pdf

8 VSC - New variable speed

Power kVA:   8 kVA

Frequency:   50Hz

RPM:                  2,200 – 3,000 rpm

Phase:             Single

Data sheet pdf

10 GS/GSC

Power kVA:  9.4 kVA

Frequency:  50Hz

RPM:                 1,500

Phase:            Single

Data sheet pdf

11 GT/GTC

Power kVA:  10.5 kVA

Frequency:  50Hz

RPM:                  1,500

Phase:             Three

Data sheet pdf

12 VSC - New variable speed

Power kVA:  12 kVA

Frequency:  50Hz

RPM:                  2,300 – 2,900 rpm

Phase:             Single

Data sheet pdf

14 GS/GSC

Power kVA:  13.9 kVA

Frequency:  50Hz

RPM:                  1,500

Phase:             Single

Data sheet pdf

G-15M-3

Power kVA:  15 kVA    Space Saver

Frequency:  50Hz     No canopy option

RPM:                  3,000

Phase:             Single

Data sheet pdf

G-15T-3

Power kVA:  15 kVA    Space Saver

Frequency:  50Hz     No canopy option

RPM:                 3,000

Phase:            Three

Data sheet pdf

16 VSC - New variable speed​

Power kVA:  16 kVA    TBC

Frequency:  50Hz       Coming soon!

RPM:                  2,300 – 2,900 rpm    TBC

Phase:             Single

Data sheet:  tbc

17 GT/GTC

Power kVA:  16.4 kVA

Frequency:  50Hz

RPM:                  1,500

Phase:             Three

Data sheet pdf

20 GS/GSC

Power kVA:  20.1 kVA

Frequency:  50Hz

RPM:                  1,500

Phase:             Single

Data sheet pdf

25 GT/GTC

Power kVA:  24.3 kVA

Frequency:  50Hz

RPM:                  1,500

Phase:             Three

Data sheet pdf

G-25M-3

Power kVA:  25 kVA   Space Saver

Frequency:  50Hz     No canopy option

RPM:                 3,000

Phase:             Single

Data sheet pdf

G-25T-3

Power kVA:  25 kVA   Space Saver

Frequency:  50Hz     No canopy option

RPM:                 3,000

Phase:             Three

Data sheet pdf

29 GS/GSC

Power kVA:  28.4 kVA

Frequency:  50Hz

RPM:                  1,500

Phase:             Single

Data sheet pdf

35 GT/GTC

Power kVA:  35 kVA

Frequency:  50Hz

RPM:                  1,500

Phase:             Three

Data sheet pdf

45 GT/GTC

Power kVA:  45 kVA

Frequency:  50Hz

RPM:                  1,500

Phase:             Three

Data sheet pdf

50 GT/GTC

Power kVA:  48.9 kVA

Frequency:  50Hz

RPM:                  1,500

Phase:             Three

Data sheet pdf

68 GT/GTC

Power kVA:  68.4 kVA

Frequency:  50Hz

RPM:                  1,500

Phase:             Three

Data sheet pdf

85 GT/GTC

Power kVA:  85 kVA

Frequency:  50Hz

RPM:                  1,500

Phase:             Three

Data sheet pdf

115 GT/GTC

Power kVA:  112.4 kVA

Frequency:  50Hz

RPM:                  1,500

Phase:             Three

Data sheet pdf

165 GT/GTC

Power kVA:  157 kVA

Frequency:  50Hz

RPM:                  1,500

Phase:             Three

Data sheet pdf

Standard equipment (minimum) provided with all new gen sets

60Hz range also available.

Single phase, 60Hz

  • 8 kVA, canopy option, 12V/24V

 

  • 12 kVA, canopy option, 12V/24V

 

  • 17 kVA, canopy option, 12V/24V

 

  • 25 kVA, canopy option, 12V/24V

 

  • 32 kVA, canopy option, 12V/24V

Three phase, 60Hz

  • 10 kVA, canopy option, 12V/24V

 

  • 14 kVA, canopy option, 12V/24V

 

  • 20 kVA, canopy option, 12V/24V

 

  • 30 kVA, canopy option, 12V/24V

 

  • 40 kVA, canopy option, 12V/24V
  • 54 kVA, canopy option, 12V/24V

 

  • 60 kVA, canopy option, 12V/24V

 

  • 84 kVA, canopy option, 12V/24V

 

  • 100 kVA, canopy option, 12V/24V

 

  • 120 kVA, canopy option, 12V/24V

 

  • 180 kVA, canopy option, 12V/24V

Many additional accessories and options available...

Control Panel standard - small units

Exhaust temperature sensor

Current monitor (Amperometric transformer)

Control Panel standard - large units​

Additional panels available

Fuel leak alarm - high pressure

Anti-condensation Kit